A 10×16 shed with porch material list comes to 103 2×4 framing boards, 3 2x6s, 5 header boards and 37 pressure-treated boards, plus 31 sheets (5 floor, 9 roof OSB, 17 T1-11 siding) and 9 bundles of shingles.
The full plan: this list is printed in the 10×16 shed with porch plan, with the cut list, a board cutting plan and step-by-step 3D drawings. See the free 10×16 shed with porch preview PDF first.
10×16 shed with porch material list: the totals
| What to buy | Qty |
|---|---|
| 2×4 framing boards | 103 |
| 2×6 boards (header and ridge) | 3 |
| 2×8 to 2×12 header boards | 5 |
| Pressure-treated boards and skids | 37 |
| Floor sheets (4×8) | 5 |
| Roof sheathing, 7/16 in OSB (4×8) | 9 |
| T1-11 siding sheets | 17 |
| Shingle bundles (3-tab) | 9 |
| Roofing felt rolls (15 lb) | 1 |
| Drip edge pieces | 8 |
| Hardware and fastener lines | 56 |
Every row on this page comes from the shopping list and cut list of the 3DSHEDPLANS 10×16 shed with porch plan, 115 items grouped by building stage. Nothing here is a rule of thumb from another size.
What this 10×16 list assumes
- Size: 16 ft by 10 ft under one roof: a 12 x 10 ft room (120 sq ft) and a 4 ft deep open porch across the 10 ft door end.
- Roof: gable roof at 6/12 over the room and the porch, 3-tab shingles over OSB and 15 lb felt.
- Floor: pressure-treated skids and joists under the room and the porch, tongue and groove floor sheets in the room and pressure-treated 5/4×6 deck boards on the porch.
- Walls and porch: 2×4 room walls with 5/8 in T1-11 siding; two notched 4×6 posts carry a 2-ply 2×8 front beam, with rails and 2×2 balusters on the porch sides.
Shopping list by stage
Lumber sizes are nominal: a 2×4 measures about 1 1/2 x 3 1/2 in, as the American Wood Council explains. Check the grade stamp on sheet goods; the APA trademark guide shows how to read it. A row marked – is cut from an offcut of a board already on the list.
Foundation and floor
| Item | Qty | For |
|---|---|---|
| Pressure-treated 2×4 x 8 ft | 1 | Porch corner block (under the post base) (2 @ 1′ 1 3/4″) |
| Pressure-treated 2×6 x 10 ft | 14 | Floor joist (13 @ 9′ 9″); Floor joist (doubled under the door wall) (1 @ 9′ 9″) |
| Pressure-treated 2×6 x 16 ft | 2 | Rim joist (band) (2 @ 16′ 0″) |
| Pressure-treated 4×4 x 16 ft, ground contact (UC4A or higher) | 4 | Skid (4 @ 16′ 0″) |
| Floor decking: sheet 4×8 3/4 T&G plywood | 5 | Floor deck: the lettered pieces on the decking map (step Floor decking) |
Front wall
| Item | Qty | For |
|---|---|---|
| 2×4 x 12 ft | 3 | Front wall plate (2 @ 12′ 0″); Front wall cap plate (1 @ 11′ 5″) |
| 2×4 x 14 ft | 2 | Front trimmer (2 @ 6′ 1″); Front trimmer (2 @ 6′ 10 3/4″) |
| 2×4 x 8 ft | 14 | Front wall stud (11 @ 7′ 6″); Front cripple (2 @ 11 1/2″); Front lower cripple (2 @ 2′ 11 1/2″); Front sill (1 @ 3′ 0″) |
| 2×6 x 8 ft | 1 | Front header (2×6 doubled + 1/2 ply) (2 @ 3′ 3″) |
| Front header filler: 1/2 plywood strip 2×6 deep, 3′ 3″ long | – | Not bought separately: rip it from the 1/2 in plywood sheet for the eave soffit (Fascia and soffit list); buy that sheet now, with the walls |
Back wall
| Item | Qty | For |
|---|---|---|
| 2×4 x 12 ft | 3 | Back wall plate (2 @ 12′ 0″); Back wall cap plate (1 @ 11′ 5″) |
| 2×4 x 14 ft | 1 | Back trimmer (2 @ 6′ 10 3/4″) |
| 2×4 x 8 ft | 11 | Back wall stud (11 @ 7′ 6″) |
Left wall
| Item | Qty | For |
|---|---|---|
| 2×4 x 10 ft | 3 | Left wall plate (2 @ 9′ 4 3/4″); Left wall cap plate (1 @ 10′ 0″) |
| 2×4 x 14 ft | 1 | Left trimmer (2 @ 6′ 5″) |
| 2×4 x 8 ft | 6 | Left wall stud (6 @ 7′ 6″) |
| 2×8 x 12 ft | 1 | Left header (2×8 doubled + 1/2 ply) (2 @ 5′ 3″) |
| Left cripple: 2×4, 4 @ 5 3/4″ | – | Not bought separately: cut from the front lower cripple, front trimmer and left trimmer offcuts |
| Left header filler: 1/2 plywood strip 2×8 deep, 5′ 3″ long | – | Not bought separately: rip it from the 1/2 in plywood sheet for the eave soffit (Fascia and soffit list); buy that sheet now, with the walls |
Right wall
| Item | Qty | For |
|---|---|---|
| 2×4 x 10 ft | 3 | Right wall plate (2 @ 9′ 4 3/4″); Right wall cap plate (1 @ 10′ 0″) |
| 2×4 x 8 ft | 8 | Right wall stud (8 @ 7′ 6″) |
Wall siding
| Item | Qty | For |
|---|---|---|
| Wall siding: sheet 4×8 5/8 T1-11 | 12 | Wall siding and sheathing in one: the lettered pieces on each wall’s siding map |
| Z-flashing (wall siding to gable siding): 10 ft piece | 2 | The joint between the wall siding and the gable siding |
| Z-flashing for the porch gable over the front beam trim, 10 ft: each | 2 | Over the porch front cap plate, the front beam trim slides under it (Gable siding; Porch rails and trim) |
Roof framing
| Item | Qty | For |
|---|---|---|
| 2×4 x 10 ft | 5 | Frieze block (over the eave walls, top beveled) (16 @ 1′ 1″); Collar tie (5 @ 4′ 10 9/16″) |
| 2×4 x 12 ft | 10 | Rafter tie (interior pairs, at the plates) (10 @ 10′ 0″) |
| 2×4 x 14 ft | 15 | Rafter (26 @ 6′ 4 15/16″); Fly rafter (rake) (4 @ 6′ 4 15/16″) |
| 2×4 x 8 ft (1 of them a full 96 in board, not a 92 5/8 in precut stud) | 6 | Ridge splice cleat (2×4 flat under the ridge joint) (1 @ 2′ 0″); Frieze block (over the eave walls, top beveled) (6 @ 1′ 1 3/4″); Center gable stud (under ridge) (3 @ 2′ 2 13/16″); Gable end stud (6 @ 1′ 1 1/16″); Gable end stud (6 @ 2′ 5 1/16″) |
| 2×6 x 10 ft | 1 | Ridge board (1 piece @ 9′ 8″) |
| 2×6 x 8 ft | 1 | Ridge board (1 piece @ 7′ 0″) |
| Lookout block (rake overhang): 2×4, 16 @ 2 1/2″ | – | Not bought separately: cut from the center gable stud, collar tie and rafter offcuts |
| Frieze block (over the eave walls, top beveled): 2×4, 2 @ 1′ 0 1/4″ | – | Not bought separately: cut from the frieze block offcuts |
| Gable end stud: 2×4, 6 @ 1′ 9 1/16″ | – | Not bought separately: cut from the collar tie, front sill and ridge splice cleat offcuts |
| Gable corner nailer (2×4 flat on the cap plate under each end rafter): 2×4, 6 @ 1′ 1 5/8″ | – | Not bought separately: cut from the rafter tie offcuts |
| Gable vent sill and header (flat): 2×4, 4 @ 1′ 2 1/2″ | – | Not bought separately: cut from the front lower cripple, front sill and rafter tie offcuts |
| Gable vent side stud (between sill and header): 2×4, 4 @ 1′ 0″ | – | Not bought separately: cut from the front trimmer and rafter tie offcuts |
Roof covering
| Item | Qty | For |
|---|---|---|
| Roof sheathing: sheet 4×8 7/16 OSB | 9 | Roof deck: the lettered pieces on the sheathing map |
| Roofing felt: roll 15 lb (400 sq ft) | 1 | Underlayment over the roof sheathing, under the shingles |
| Asphalt shingles: bundle 3-tab, 26 shingles, incl. starter and ridge cap | 9 | Starter strips, the roof courses and the cap pieces (Shingles step) |
| Drip edge: 10 ft piece | 8 | Eaves under the felt, rakes over it |
Fascia, soffit and gable siding
| Item | Qty | For |
|---|---|---|
| 1×6 x 10 ft | 2 | Fascia (eave) (2 pieces @ 9′ 8″) |
| 1×6 x 14 ft | 2 | Fascia (rake; both ends plumb and parallel: 6′ 4 7/8″ along either edge, length given tip to tip) (4 @ 6′ 7 5/8″) |
| 1×6 x 8 ft | 2 | Fascia (eave) (2 pieces @ 7′ 0″) |
| Gable siding: sheet 4×8 5/8 T1-11 | 3 | The gable triangles above the walls (gable siding map) |
| Eave soffit (ripped 1/2 plywood): sheet 4×8 1/2 plywood | 2 | Soffit strips under the eaves (Fascia and soffit step) |
Door, window and trim
| Item | Qty | For |
|---|---|---|
| 1×12 x 12 ft | 1 | Beam trim, front (1×12 primed, ripped to the beam and plate face) (1 @ 10′ 1 1/2″) |
| 1×12 x 8 ft | 1 | Beam trim, side (1×12 primed, ripped to the beam and plate face) (2 @ 3′ 10 13/16″) |
| 1×2 x 8 ft | 2 | Door stop (header) (1 @ 5′ 0″); Door astragal (fixed leaf edge) (1 @ 6′ 5 1/4″) |
| 1×4 x 12 ft | 1 | Door rail (6 @ 1′ 10 5/8″) |
| 1×4 x 14 ft | 5 | Corner trim (door-wall faces at the porch corners: deck line up to the side beam) (2 @ 6′ 11 3/8″); Door casing (sides) (2 @ 6′ 10″); Door stile (4 @ 6′ 5 3/4″); Door Z brace (along either edge) (4 @ 3′ 2 7/16″) |
| 1×4 x 16 ft | 2 | Corner trim (eave-wall faces) (4 @ 7′ 11 1/8″) |
| 1×4 x 8 ft | 5 | Corner trim (gable-wall faces, right wall) (2 @ 7′ 9 7/16″); Door casing (head, between the side casings) (1 @ 5′ 0″); Window casing (sides) (2 @ 3′ 0″); Window casing (head and sill) (2 @ 3′ 7″) |
| 2×4 x 10 ft | 2 | Porch side plate (2 @ 4′ 0″); Porch front plate (1 @ 9′ 5″) |
| 2×4 x 12 ft | 1 | Porch front cap plate (laps both porch eave caps) (1 @ 10′ 0″) |
| 2×4 x 8 ft | 1 | Porch eave cap plate (on the porch side plate, front cap to the door wall’s cap) (2 @ 3′ 8 1/2″) |
| 2×8 x 10 ft | 4 | Porch side beam ply (4 @ 4′ 3 1/2″); Porch front beam ply (2 @ 9′ 1″) |
| Pressure-treated 2×2 x 10 ft | 4 | Porch baluster (2×2) (16 @ 2′ 1 1/2″) |
| Pressure-treated 2×4 x 14 ft | 1 | Porch rail (2×4 on edge: a bottom and a top rail each side) (4 @ 3′ 5 5/8″) |
| Pressure-treated 2×4 x 8 ft | 2 | Porch beam bearing block (2×4 PT, bolted to the post) (2 @ 2′ 0″); Porch rail nailer (2×4 flat on each door-wall corner board) (2 @ 2′ 8 1/2″) |
| Pressure-treated 4×4 x 12 ft | 1 | Porch knee brace (4×4 PT, 45 deg both ends, cuts mirrored, long points on one edge; two at each post) (4 @ 2′ 9 15/16″) |
| Pressure-treated 4×6 x 8 ft | 2 | Porch post (4×6, notch 3 1/2 x 7 1/4 in at the outer top; measure on the frame) (2 @ 7′ 7 1/8″) |
| Door leaf siding (one new sheet per leaf; the cut-out is too short): sheet 4×8 5/8 T1-11 | 2 | The two door leaves (Door step) |
| Door hinges (heavy T-strap, 8 in strap or longer, galvanized): each | 6 | Hanging the door leaves |
| Door handle and latch (pull handle + gate latch or hasp with a padlock loop): set | 1 | The active door leaf |
| Door sweep, brush type, 36 in, with its screws (cut to 2′ 5 1/16″ for the active leaf and 2′ 4 13/16″ for the fixed leaf): each | 2 | The bottom edge of each door leaf, inside face (Door step) |
| Door hold-open hook: 3/16 in galvanized chain 34 in with a snap hook, and 2 screw eyes (one in the leaf, one in the porch post): each | 2 | Holding the open door in wind (Door step) |
| Prefabricated window, 36 x 36 in rough opening: each | 1 | The window opening (window step) |
| Porch deck board, PT 5/4×6 x 8 ft (two pieces 3′ 11 7/8″ from each board, 21 pieces): each | 11 | The porch floor in front of the room, two pieces from each board (Porch deck boards) |
Hardware
| Item | Qty | For |
|---|---|---|
| Carriage bolts 1/4 x 2 in, galvanized, with washers and nuts (3 per hinge strap): each | 18 | The hinge straps on the door leaf, nuts inside (Door step) |
| Aluminum threshold cap (angle about 1 x 1 1/2 in), 5 ft piece: each | 1 | The deck edge across the door opening (Door step) |
| Barrel bolts for the fixed leaf (3 in, 1 1/2 in wide or narrower, to fit on the astragal): each | 2 | Holding the fixed leaf closed, top and bottom |
| Framing nails 3 1/2 in (16d) hot-dip galvanized (about 1112 nails + 10 %): lb | 31 | Every framing joint (fastener schedule) |
| Siding nails 2 1/2 in (8d) hot-dip galvanized: lb | 14 | T1-11 siding and trim |
| Sheathing nails 2 1/2 in (8d) for OSB: lb | 5 | Roof sheathing: 6 in apart on the edges, 12 in in the field |
| Roofing nails 1 1/4 in galvanized: lb | 5 | Shingles and drip edge |
| Deck screws 2 in, coated for treated lumber (or 6d hot-dip galvanized ring-shank nails): lb | 3 | Floor decking: 6 in apart on the edges, 12 in in the field |
| Construction adhesive, 10 oz tubes: each | 7 | A bead on each joist under the floor decking |
| Hurricane ties (rafter to plate), H2.5A type or equal, 10 nails each: each | 22 | Each rafter to the top plate |
| Framing angles for the end rafters at the 4 corners (A34 type, about 2 1/2 in long, or equal, 8 nails each): each | 4 | The two end rafters to the plates at the 4 corners, where the side wall covers the inside face |
| Framing angles for the floor frame on the skids, one at every joist-to-skid crossing (A34 type, about 2 1/2 in long, 18 ga, ZMAX or hot-dip galvanized for treated wood, or equal), 8 connector nails each: each | 56 | One at every joist-to-skid crossing (Floor frame step) |
| Ground anchors, screw-in auger type, 30 in or longer, galvanized, each with a galvanized steel strap (an empty shed on skids slides in a strong gust: Anchor the shed): each | 6 | Holding the shed down in wind: along the two outside skids (Anchor the shed step) |
| Structural wood screws 1 1/2 in, exterior (anchor straps: 4 into the skid and 2 into the rim per anchor): each | 36 | Each ground-anchor strap to the outside skid and the rim joist (Anchor the shed step) |
| Crushed stone 3/4 in for the pad (loose, before tamping): cu yd | 3.2 | The gravel pad under the skids (Preparation step) |
| Pressure-treated 4×6 x 10 ft, ground contact (UC4A or higher), for the gravel pad frame: each | 4 | The frame around the gravel pad and the landing (Preparation step) |
| Pressure-treated 4×6 x 16 ft, ground contact (UC4A or higher), for the gravel pad frame: each | 2 | The frame around the gravel pad and the landing (Preparation step) |
| Rebar stakes 1/2 in (#4) x 24 in, for the pad frame: each | 24 | Pinning the pad frame to the ground: about every 4 ft and near each end of every piece (Preparation step) |
| Galvanized timber spikes 3/8 in x 10 in for the pad frame corners (2 per corner): each | 8 | Joining the pad frame’s corners (Preparation step) |
| Exterior paint and primer in one (2 coats, about 526 sq ft each): gallon | 4 | Siding, trim and door, two coats |
| Exterior caulk: tube | 3 | Trim joints and the window and door casings |
| Roofing cap nails 1 in (felt): lb | 1 | Holding the felt down |
| Wood shims (door and window): bundle | 1 | Plumbing the door and the window in their openings |
| Roofing cement, 10 oz tubes: each | 2 | Sealing the last cap pieces and any exposed nail heads |
| Exterior screws 1 1/4 in (door frame to T1-11): lb | 1 | Door frame boards to the T1-11 leaves |
| Exterior screws 3 in (hinge T-parts through the casing into the framing; wall corners where a hammer will not swing): box | 1 | Hinge T-parts through the casing into the king stud and trimmer |
| Exterior screws 3 1/2 in (roof foot stops): box | 1 | The roof foot stops: 2 through the 2×4 and the sheathing into each rafter it crosses |
| Louvered gable vent 8 x 12 in: each | 2 | Vent openings in the gable ends |
| Connector nails 1 1/2 in (hot-dip galvanized, rated for treated wood; hurricane ties and straps): lb | 9 | Every hurricane tie, strap and framing angle |
| Flashing tape 4 in (window opening): roll | 1 | Wrapping the window rough opening |
| Drip cap (Z-flashing) over the window and door head casings, 10 ft: each | 1 | Over the window and door head casings |
| Staples 3/8 in for the staple gun (insect screen): box | 1 | Stapling the insect screen over the vent gaps and holes |
| Insect screen for vent holes/gaps, 2 ft x 25 ft: roll | 1 | Behind the vent holes and the soffit vent gaps |
| Temporary braces 2×4 x 12 ft (reuse later): 2 plumb braces per wall section and the diagonal each section is squared with; each wall’s plumb braces come off once that wall is sided: each | 12 | Holding the walls plumb and square until the siding is on, reused later |
| Temporary braces for the center gable studs 2×4 x 12 ft (step Ridge): each | 6 | Holding the two center gable studs plumb while the ridge goes on (step Ridge) |
| 2×4 x 8 ft for the flat decking seam blocks (step Floor decking): each | 2 | Flat 2×4 blocks between the joists under the last decking seam (dashed on the decking map) |
| 2×4 x 8 ft for 8 stakes 24 in, pointed (one per plumb brace): each | 3 | Staking the plumb braces outside the walls |
| 2×4 x 8 ft for 14 deck cleats 12 in (one per plumb brace once it moves inside, 6 for the center gable stud braces): each | 2 | Screwed to the deck to hold the brace feet inside |
| Standoff post base for 4×6, 1 in standoff (the post end sits 1 in above the deck), the type made for fixing to a wood deck or wood framing (screw holes in the base plate, not the one-hole concrete type), ZMAX or hot-dip galvanized, with the structural screws its maker lists for wood, long enough to reach 1 1/2 in or more into the framing below the 1 in deck boards (2 1/2 in or longer), and the post fasteners it lists: each | 2 | Under each porch post, screwed to the floor frame (Porch posts and beams) |
| Carriage bolts 1/2 x 5.5 in, hot-dip galvanized, washer and nut (side beam to post, nut in a counterbore): each | 4 | Each side beam through its post’s tongue, two per post, nut in a counterbore (Porch posts and beams) |
| Carriage bolts 1/2 x 8 in, hot-dip galvanized, washer and nut (bearing blocks through the post): each | 4 | Each front beam bearing block through its post, two per block (Porch posts and beams) |
| Structural wood screws 10 in, exterior coated (through the post’s tongue and the side beam into the front beam end): each | 4 | Through each post’s tongue and side beam into the front beam end (Porch posts and beams) |
| Structural wood screws 8 in, exterior coated (knee braces: 2 into the beam at each brace, 2 into the block and post at each front brace): each | 12 | The top of every knee brace into its beam; the front braces into block and post (Porch posts and beams) |
| Structural wood screws 6 in, exterior coated (side knee braces into the post’s back face): each | 4 | Side knee braces into the post’s back face (Porch posts and beams) |
| Strap ties 16 in, LSTA type or equal, ZMAX or hot-dip galvanized (across each eave cap joint at the door wall): each | 2 | Across each eave cap joint at the door wall, nailed on before the rafters go up (Porch posts and beams) |
| L-flashing 2 x 4 in, galvanized or aluminum, 10 ft (door-wall siding bottom over the porch deck): each | 1 | Behind the door wall’s siding bottom, 4 in leg up the wall, 2 in leg on the porch deck (Join the walls) |
| Structural wood screws 5 in, exterior coated (rail nailers through the corner boards and siding into the corner studs): each | 6 | Each rail nailer through the corner board and siding into the corner stud (Porch rails and trim) |
| Temporary post brace 2×4 x 8 ft (two per porch post; the 2x4s go to offcuts after): each | 4 | Holding each porch post plumb from Porch posts and beams until the roof sheathing is on (Porch rails and trim) |
| 2×4 x 8 ft for 4 brace cleats 12 in (one under each temporary post brace foot): each | 1 | Holding each porch post plumb from Porch posts and beams until the roof sheathing is on (Porch rails and trim) |
| Porch beam filler strips (one sheet 4×8 1/2 plywood): rip 8 ft strips, two 7 1/4 in for the side beams, cut 4′ 3 1/2″, and two 7 1/4″ for the front beam, cut 6′ 0″ and 3′ 1″ (the front strip is two pieces end to end): each | 1 | The 1/2 in strip between the plies of each porch beam (Porch posts and beams) |
| Temporary ridge post 2×4 x 12 ft (holds the ridge joint while the rafters go on; offcuts after): each | 1 | Holding the roof framing up until the rafters are in, reused later |
| End-cut wood preservative, 1 qt (post notches and post bottoms): each | 1 | Every cut face of the post notches and post bottoms (Porch posts and beams) |
| Finish nails 2 in, hot-dip galvanized, 1 lb (beam trim): each | 1 | The 1x trim wrapped round the porch beams (Porch rails and trim) |
| Deck screws 2 1/2 in, exterior, 5 lb box (porch deck boards and balusters: about 274): each | 1 | Porch deck boards (Porch deck boards) and balusters (Porch rails and trim) |
| Exterior screws 3 in (porch rails, post braces and cleats: about 60): each | 60 | Porch rails, post braces and brace cleats |
| Exterior wood filler (brace cleat screw holes in the deck): each | 1 | The brace cleat screw holes in the porch deck (Porch rails and trim) |
Cut list: every part
Cut and label the parts one stage at a time. The cutting plan in the PDF shows which board each part comes from.
| Part | Lumber | Cut length | Qty |
|---|---|---|---|
| Skid | PT 4×4 | 16′ 0″ | 4 |
| Rim joist (band) | PT 2×6 | 16′ 0″ | 2 |
| Floor joist | PT 2×6 | 9′ 9″ | 13 |
| Front wall plate | 2×4 | 12′ 0″ | 2 |
| Front wall cap plate | 2×4 | 11′ 5″ | 1 |
| Front wall stud | 2×4 | 7′ 6″ | 11 |
| Front cripple | 2×4 | 11 1/2″ | 2 |
| Front header (2×6 doubled + 1/2 ply) | 2×6 | 3′ 3″ | 2 |
| Front lower cripple | 2×4 | 2′ 11 1/2″ | 2 |
| Front sill | 2×4 | 3′ 0″ | 1 |
| Front trimmer | 2×4 | 6′ 1″ | 2 |
| Front trimmer | 2×4 | 6′ 10 3/4″ | 2 |
| Back wall plate | 2×4 | 12′ 0″ | 2 |
| Back wall cap plate | 2×4 | 11′ 5″ | 1 |
| Back wall stud | 2×4 | 7′ 6″ | 11 |
| Back trimmer | 2×4 | 6′ 10 3/4″ | 2 |
| Left wall plate | 2×4 | 9′ 4 3/4″ | 2 |
| Left wall cap plate | 2×4 | 10′ 0″ | 1 |
| Left wall stud | 2×4 | 7′ 6″ | 6 |
| Left cripple | 2×4 | 5 3/4″ | 4 |
| Left header (2×8 doubled + 1/2 ply) | 2×8 | 5′ 3″ | 2 |
| Left trimmer | 2×4 | 6′ 5″ | 2 |
| Right wall plate | 2×4 | 9′ 4 3/4″ | 2 |
| Right wall cap plate | 2×4 | 10′ 0″ | 1 |
| Right wall stud | 2×4 | 7′ 6″ | 8 |
| Rafter | 2×4 | 6′ 4 15/16″ | 26 |
| Fly rafter (rake) | 2×4 | 6′ 4 15/16″ | 4 |
| Lookout block (rake overhang) | 2×4 | 2 1/2″ | 16 |
| Ridge board | 2×6 | 16′ 8″ | 1 |
| Ridge splice cleat (2×4 flat under the ridge joint) | 2×4 | 2′ 0″ | 1 |
| Rafter tie (interior pairs, at the plates) | 2×4 | 10′ 0″ | 10 |
| Frieze block (over the eave walls, top beveled) | 2×4 | 1′ 0 1/4″ | 2 |
| Frieze block (over the eave walls, top beveled) | 2×4 | 1′ 1″ | 16 |
| Frieze block (over the eave walls, top beveled) | 2×4 | 1′ 1 3/4″ | 6 |
| Collar tie | 2×4 | 4′ 10 9/16″ | 5 |
| Center gable stud (under ridge) | 2×4 | 2′ 2 13/16″ | 3 |
| Gable end stud | 2×4 | 1′ 1 1/16″ | 6 |
| Gable end stud | 2×4 | 1′ 9 1/16″ | 6 |
| Gable end stud | 2×4 | 2′ 5 1/16″ | 6 |
| Gable corner nailer (2×4 flat on the cap plate under each end rafter) | 2×4 | 1′ 1 5/8″ | 6 |
| Gable vent sill and header (flat) | 2×4 | 1′ 2 1/2″ | 4 |
| Gable vent side stud (between sill and header) | 2×4 | 1′ 0″ | 4 |
| Fascia (eave) | 1×6 | 16′ 8″ | 2 |
| Fascia (rake; both ends plumb and parallel: 6′ 4 7/8″ along either edge, length given tip to tip) | 1×6 | 6′ 7 5/8″ | 4 |
| Corner trim (eave-wall faces) | 1×4 | 7′ 11 1/8″ | 4 |
| Corner trim (gable-wall faces, right wall) | 1×4 | 7′ 9 7/16″ | 2 |
| Corner trim (door-wall faces at the porch corners: deck line up to the side beam) | 1×4 | 6′ 11 3/8″ | 2 |
| Door casing (sides) | 1×4 | 6′ 10″ | 2 |
| Door casing (head, between the side casings) | 1×4 | 5′ 0″ | 1 |
| Window casing (sides) | 1×4 | 3′ 0″ | 2 |
| Window casing (head and sill) | 1×4 | 3′ 7″ | 2 |
| Door stile | 1×4 | 6′ 5 3/4″ | 4 |
| Door rail | 1×4 | 1′ 10 5/8″ | 6 |
| Door Z brace (along either edge) | 1×4 | 3′ 2 7/16″ | 4 |
| Door stop (header) | 1×2 | 5′ 0″ | 1 |
| Door astragal (fixed leaf edge) | 1×2 | 6′ 5 1/4″ | 1 |
| Floor joist (doubled under the door wall) | PT 2×6 | 9′ 9″ | 1 |
| Porch corner block (under the post base) | PT 2×4 | 1′ 1 3/4″ | 2 |
| Porch post (4×6, notch 3 1/2 x 7 1/4 in at the outer top; measure on the frame) | PT 4×6 | 7′ 7 1/8″ | 2 |
| Porch beam bearing block (2×4 PT, bolted to the post) | PT 2×4 | 2′ 0″ | 2 |
| Porch knee brace (4×4 PT, 45 deg both ends, cuts mirrored, long points on one edge; two at each post) | PT 4×4 | 2′ 9 15/16″ | 4 |
| Porch side beam ply | 2×8 | 4′ 3 1/2″ | 4 |
| Porch front beam ply | 2×8 | 9′ 1″ | 2 |
| Porch side plate | 2×4 | 4′ 0″ | 2 |
| Porch front plate | 2×4 | 9′ 5″ | 1 |
| Porch eave cap plate (on the porch side plate, front cap to the door wall’s cap) | 2×4 | 3′ 8 1/2″ | 2 |
| Porch front cap plate (laps both porch eave caps) | 2×4 | 10′ 0″ | 1 |
| Porch rail (2×4 on edge: a bottom and a top rail each side) | PT 2×4 | 3′ 5 5/8″ | 4 |
| Porch rail nailer (2×4 flat on each door-wall corner board) | PT 2×4 | 2′ 8 1/2″ | 2 |
| Porch baluster (2×2) | PT 2×2 | 2′ 1 1/2″ | 16 |
| Beam trim, side (1×12 primed, ripped to the beam and plate face) | 1×12 | 3′ 10 13/16″ | 2 |
| Beam trim, front (1×12 primed, ripped to the beam and plate face) | 1×12 | 10′ 1 1/2″ | 1 |
Before you order
Rules for sheds vary by town and HOA, so check your local permit office before you buy lumber. Keep every part that touches the ground pressure treated: the USDA Wood Handbook explains why wet, untreated wood decays. The shed foundation options guide compares skids, blocks and gravel pads, and the shed material calculator checks totals fast.
Get the full plan
The 10×16 shed with porch plan is a 3DSHEDPLANS PDF with this material list, the cutting plan and step-by-step 3D drawings from the skids to the shingles. See the free 10×16 shed with porch preview PDF to check the format, or compare sizes on the gable shed plans.
Frequently asked questions
How many 2x4s do I need for a 10×16 shed with porch?
103 2×4 framing boards in the stock lengths listed by stage below, plus 3 2x6s, 5 header boards and 37 pressure-treated boards for the floor and base.
How many sheets of plywood, OSB and T1-11 for a 10×16 shed with porch?
5 floor sheets, 9 sheets of 7/16 in OSB for the roof and 17 sheets of 5/8 in T1-11 siding. The tables below list each one with what it is for.
How many bundles of shingles for a 10×16 shed with porch roof?
9 bundles of 3-tab shingles including the starter course, over 1 roll of 15 lb felt and 8 pieces of drip edge.
What rafters does the 10×16 shed with porch use?
46 rafter parts in all, 3 cut lengths from 1' 1 5/8" to 6' 4 15/16". Each part and its length is in the cut list below. For snow loads, check your local permit office.
Is there a printable 10×16 shed with porch plan with this list?
Yes. The 10×16 shed with porch plan PDF prints this list, the cut list and a board cutting plan with step-by-step 3D drawings. Its free preview PDF shows the format first.
Shed building guides
- 8×20 Firewood Shed Material List: Lumber, Slats, Hardware
- 8×8 Lean-To Shed Material List: Lumber, Sheets, Hardware
- 8×8 Hip Roof Shed Material List: Lumber, Sheets, Hardware
- 8×20 Lean-To Shed Material List: Lumber, Sheets, Hardware
- 8×20 Hip Roof Shed Material List: Lumber, Sheets, Hardware
- 8×16 Gable Shed Material List: Lumber, Sheets, Hardware




